A method is described for specifying CRT traces in terms of visual measures of width and central luminance. Trace width is measured with an image doubler which produces 2 parallel images of the CRT trace; width is defined in terms of the distance between the centers of the 2 images when they just appear to merge. Central luminance of the trace is measured with a magnifying system in conjunction with a Macbeth illuminometer. The magnifier produces a real image of the trace sufficiently enlarged to fill the field of the Macbeth. Matching is performed in the usual way; the appropriate conversion factor is applied to the Macbeth reading. Estimates of intra-observer and inter-observer variability are given for width and luminance measures. The method of measuring central luminance is compared experimentally with an alternative method involving a direct monocular match.