Investigation Of The Application Of Electric Current During Zone Refining

Item

Title
Investigation Of The Application Of Electric Current During Zone Refining
Date
1961
Index Abstract
Not Available
Photo Quality
Undetermined
Report Number
WADD TR 61-90
Creator
Thomas, Louis L.
Corporate Author
Research Chemicals, Inc.
Extent
49
PB Number
PB181114
Identifier
AD0613534
Access Rights
Unknown
Distribution Classification
1
DTIC Record Exists
No
Distribution Change Authority Correspondence
None
Abstract
An investigation of the effects of axial direct current during a zone refining process has been continued. Optimum current direction and limiting current densities have been established. Results for germanium indicate that the segregation rate is increased when the current flows opposite to the direction of zone travel, and is decreased when the current is reversed. The magnitude of the effect is larger than the theoretical rate of diffusion of ions in an electric field, and the optimum current direction is opposite to that predicted from considerations of interface stability due to the Peltier effect.
Report Availability
Not available via Contrails
Date Issued
1961-07
Index In
U.S. Government Research Reports
Type