Title
-
Goniophotometer to Measure Diffusion Characteristics of Rear Projection Screens
-
Date
-
1965
-
Index Abstract
-
Not Available
-
Photo Quality
-
Complete
-
Report Number
-
AMRL TR 65-207
-
Creator
-
Smith, Edgar A.
-
Williams, Guy S.
-
Mohlman, Henry T.
-
Corporate Author
-
University of Dayton Research Institute
-
Laboratory
-
Aerospace Medical Research Laboratories
-
Extent
-
28
-
Identifier
-
AD0631315
-
Access Rights
-
Distribution of this document is unlimited
-
Distribution Classification
-
1
-
Contract
-
AF 33(615)-2348
-
DoD Project
-
1710
-
DoD Task
-
171007
-
DTIC Record Exists
-
No
-
Distribution Change Authority Correspondence
-
None
-
Distribution Conflict
-
No
-
Abstract
-
A goniophotometer was developed for use in measuring the diffusion characteristics of rear projection screen materials. Rear projection screens provide a wide range of possible diffusion characteristics. Similarly, different applications require different characteristics. The goniophotometer will facilitate the selection of screens most suitable for a particular application. Primary components of the device include a light tight chassis, a light source mounted on an arm which can be rotated plus or minus 60 degrees, a holder for screen specimens, a specifically designed photometer, and two interior ambient light panels and associated interior foot candle meters. Schematics, wiring diagrams, and drawings necessary for the fabrication of additional units are included.
-
Report Availability
-
Full text available
-
Date Issued
-
1965-12
-
Provenance
-
RAF Centre of Aviation Medicine
-
Type
-
report
-
Format
-
1 online resource